tutorial

Same ducts. Less room for the adapter.

· 9 views

The two ducts are already chosen. Then the cabinet layout changes, leaving less room between them. You still need the same connection sizes—but the adapter needs to occupy less space along its length.

Specify a shorter transition, then measure the complete adapter. In this Nora3D example, keeping the connection-size inputs at 110 and 52 mm while reducing the transition input from 62 to 54 mm produced a new variant with an overall axial span of 104 mm, down from 112 mm. That is 8 mm less length to account for in the installation.

Change the space requirement, keep the connection brief

Our earlier duct-adapter example started with two different duct sizes. This time, those inputs are settled. The design question is how to shorten the run between them.

For a cabinet with less axial room, the brief becomes:

Keep the 110 mm and 52 mm connection-size inputs. Use a 54 mm transition and check the complete adapter's end-to-end span against the available space.

This example compares two separately generated, saved variants. The video shows construction of the new, shorter version. It gives you a concrete alternative to evaluate against the original dimensions.

A 54 mm transition is not a 54 mm adapter

The tapered section is only part of the shape. The end sections also occupy space. Planning around the transition input alone would leave them out of the length calculation.

That is why the useful comparison includes both the design input and the measured overall span:

Dimension Earlier variant Shorter variant
Large connection input 110 mm 110 mm
Small connection input 52 mm 52 mm
Transition-length input 62 mm 54 mm
Measured overall axial span 112 mm 104 mm

The other two measured outer extents remained 116 mm and approximately 115.804 mm. In this comparison, the new version takes up less space along its axis while retaining the same overall bounds in the other two directions.

This is the practical value of generating a candidate from a specific brief: you can compare the space the complete part occupies, instead of guessing from the taper length or a perspective view.

Review the shorter version in its intended location

An 8 mm reduction is useful information. The next decision is whether the complete arrangement works in your cabinet.

Start with the available end-to-end space and compare it with the 104 mm model span. Then consider how the ends will engage with the existing ducts. Insertion depth changes the installed arrangement, and assembly access can require room beyond the part itself.

Treat the 110 and 52 mm values as the connection inputs for this design. When reviewing your own hardware, measure the relevant mating surfaces and choose the clearance for that connection. Overall model bounds and local connection dimensions answer different questions.

For a repeatable way to organize that review, see how to check a functional CAD design: identify what must change, what must stay, and which measurements will settle the decision.

Keep a saved candidate for the next decision

The shorter variant was verified as one solid, saved and reopened. Its geometry, history and revision were restored after the construction replay.

You now have a specific candidate to return to: the same two connection-size inputs, a shorter transition, and an overall span measured at 104 mm.

Start with the space you have. Give Nora3D the dimensions that must stay. Then judge the whole part—not just the dimension you changed.

Plan your adapter in Nora3D