PCB & Electronics · Free generator
Ventilated PCB service carrier
An accessible PCB mounting carrier with four bored standoffs, cooling windows, raised cable-tie rails and a protected connector bay.
Free customization & STL download · No account needed
Open generator in a full window ↗
Edit the design. Export CAD.
Choose Continue editing in Nora3D inside the generator to keep your dimensions in an editable copy. Change features and export STEP CAD files.
Sign in to edit. Export options depend on your plan. View plans ↗
Before you print
Carrier 110 x 85 x 5. Posts on a 58 x 49 pattern, height 8 above the deck; this pattern alone does not establish board compatibility. Two raised cable rails and four mounting ears. Verify component keep-outs against your board. Geometry has been digitally checked; this template has not been physically test-printed.
Build on this design
AI CAD prompt
Use this prompt with Nora3D or your AI assistant. Review the resulting geometry before printing.
View full prompt
Create a new owned Nora3D part document. Use millimeters, world XY as the base and +Z as height. Retain named native features and expose only the controls listed below. 1. Create **Deck**, a 110 × 85 × 5 box, centered at X=0, Y=0, with its bottom at Z=0. 2. Create **Left cable rail**, a 8 × 70 × 13 box, centered at X=-49, Y=0, with its bottom at Z=5. 3. Create **Right cable rail**, a 8 × 70 × 13 box, centered at X=49, Y=0, with its bottom at Z=5. 4. Create **Connector guard**, a 70 × 6 × 22 box, centered at X=0, Y=-39, with its bottom at Z=5. 5. Create **PCB post -29 -24.5**, radius 4.5, height 8, initially along +Z, with its base center at (-29, -24.5, 5). 6. Create **PCB post -29 24.5**, radius 4.5, height 8, initially along +Z, with its base center at (-29, 24.5, 5). 7. Create **PCB post 29 -24.5**, radius 4.5, height 8, initially along +Z, with its base center at (29, -24.5, 5). 8. Create **PCB post 29 24.5**, radius 4.5, height 8, initially along +Z, with its base center at (29, 24.5, 5). 9. Unite **Deck**, **Left cable rail**, **Right cable rail**, **Connector guard**, **PCB post -29 -24.5**, **PCB post -29 24.5**, **PCB post 29 -24.5**, **PCB post 29 24.5** as **Carrier blank**. Require one connected result. 10. Create **Pilot -29 -24.5**, radius 1.4, height 10, initially along +Z, with its base center at (-29, -24.5, 5). 11. Create **Pilot -29 24.5**, radius 1.4, height 10, initially along +Z, with its base center at (-29, 24.5, 5). 12. Create **Pilot 29 -24.5**, radius 1.4, height 10, initially along +Z, with its base center at (29, -24.5, 5). 13. Create **Pilot 29 24.5**, radius 1.4, height 10, initially along +Z, with its base center at (29, 24.5, 5). 14. Create **Deck vent -24**, a 8 × 30 × 8 box, centered at X=-24, Y=0, with its bottom at Z=-1. 15. Create **Deck vent -8**, a 8 × 30 × 8 box, centered at X=-8, Y=0, with its bottom at Z=-1. 16. Create **Deck vent 8**, a 8 × 30 × 8 box, centered at X=8, Y=0, with its bottom at Z=-1. 17. Create **Deck vent 24**, a 8 × 30 × 8 box, centered at X=24, Y=0, with its bottom at Z=-1. 18. Create **Tie channel -49 -22**, a 12 × 5 × 3 box, centered at X=-49, Y=-22, with its bottom at Z=9. 19. Create **Tie channel -49 22**, a 12 × 5 × 3 box, centered at X=-49, Y=22, with its bottom at Z=9. 20. Create **Tie channel 49 -22**, a 12 × 5 × 3 box, centered at X=49, Y=-22, with its bottom at Z=9. 21. Create **Tie channel 49 22**, a 12 × 5 × 3 box, centered at X=49, Y=22, with its bottom at Z=9. 22. Create **Connector bay**, a 30 × 12 × 12 box, centered at X=0, Y=-39, with its bottom at Z=9. 23. Create **Mount -40 -35**, radius 2.5, height 8, initially along +Z, with its base center at (-40, -35, -1). 24. Create **Mount -40 35**, radius 2.5, height 8, initially along +Z, with its base center at (-40, 35, -1). 25. Create **Mount 40 -35**, radius 2.5, height 8, initially along +Z, with its base center at (40, -35, -1). 26. Create **Mount 40 35**, radius 2.5, height 8, initially along +Z, with its base center at (40, 35, -1). 27. Subtract **Pilot -29 -24.5**, **Pilot -29 24.5**, **Pilot 29 -24.5**, **Pilot 29 24.5**, **Deck vent -24**, **Deck vent -8**, **Deck vent 8**, **Deck vent 24**, **Tie channel -49 -22**, **Tie channel -49 22**, **Tie channel 49 -22**, **Tie channel 49 22**, **Connector bay**, **Mount -40 -35**, **Mount -40 35**, **Mount 40 -35**, **Mount 40 35** from **Carrier blank**, consuming the tools; name the result **PCB carrier**. ## Public controls | Control | Default | Range | Step | Meaning | | --- | ---: | --- | ---: | --- | | Connector clearance width | 30 | 24–42 | 1 | Width of the opening in the front guard. | | Connector clearance height | 12 | 8–14 | 1 | Height above the fixed lower edge at Z=9. | | Reference pilot radius | 1.4 | 1.2–1.8 | 0.1 | Fit trial for the front-left post; the other three pilots remain 2.8 mm in diameter. | All unlisted dimensions, topology and feature order remain fixed. Radius controls are radii, not diameters. These are independent numeric ranges; do not introduce unsupported formula bindings or assume a fit standard from an example value.
Adjustable dimensions
| Parameter | Default | Range | Step |
|---|---|---|---|
| Connector clearance width | 30 mm | 24–42 mm | 1 mm |
| Connector clearance height | 12 mm | 8–14 mm | 1 mm |
| Reference pilot radius | 1.4 mm | 1.2–1.8 mm | 0.1 mm |